✓ No Fix, No Cost

Est. 2008

Timegrapher readings explained for collectors

A timegrapher gives you three numbers that matter: rate (seconds gained or lost per day), amplitude (degrees of balance-wheel arc), and beat error (milliseconds of timing asymmetry). Together they tell you whether a movement is healthy, needs monitoring, or should go straight to a bench. The single fastest decision rule: if amplitude drops below roughly 250° at full wind, something is wrong regardless of what the rate says.

Quick flags to act on immediately:

  • Rate outside ±10 s/d for a typical consumer movement — regulation likely needed
  • Amplitude below ~250° at full wind, dial up — service is overdue
  • Beat error above 0.8 ms — worth investigating; above 1.2 ms, the watch needs attention
  • Large positional variance (rate swings of 20+ s/d between positions) — poise or hairspring issue

If the numbers all sit comfortably inside those ranges, the movement is performing well. If one flag appears, monitor it. If two or more appear together, the watch needs professional attention.

Key takeaways

Amplitude is the most critical single number in any timegrapher reading: a healthy movement at full wind should show at least 250–270°, and anything below 240° is a clear service trigger regardless of rate.

Point Details
Amplitude first Check amplitude before rate; below 240° at full wind means service is needed.
Demagnetise before diagnosing A steep trace and fast rate often resolve completely after demagnetisation.
Set lift angle correctly Verify the calibre’s lift angle before testing; a wrong value skews amplitude by 10–20%.
Use six positions Dial-up alone is not enough; large positional variance signals poise or hairspring issues.
Track trends, not snapshots Repeated readings over several days reveal deterioration that a single session misses.

Table of Contents

What do timegrapher readings actually measure?

A timegrapher works by placing a sensitive microphone against the watch case and listening to the escapement’s tick-tock rhythm. The device’s internal clock compares the interval between each tick to the expected beat rate of the movement, then calculates rate, amplitude, and beat error from those acoustic signals. Dedicated timing machines from manufacturers such as Witschi use precision electronics to do this with far greater consistency than a smartphone microphone ever can.

Two inputs you enter manually shape how the machine interprets what it hears:

  • Beat rate (vph): the number of vibrations per hour the movement is designed to run at — 28,800 vph for most modern Swiss movements, 21,600 for many vintage calibres
  • Lift angle: the degrees through which the lever lifts the impulse pin; getting this wrong skews the amplitude reading significantly

Neither value is measured by the machine. You look them up for the specific calibre and enter them before testing. Witschi’s technical documentation covers the measurement methodology in detail for anyone who wants to go deeper on device calibration.

How to take repeatable timegrapher readings

Consistency matters more than any single result. A reading taken on a noisy workbench after a partial wind tells you almost nothing useful. Follow this sequence every time.

Setup checklist:

  1. Set the beat rate to match the calibre (check the manufacturer’s specification sheet or a calibre database).
  2. Enter the correct lift angle for the movement (see the parameters section below for common values).
  3. Place the watch on a quiet, vibration-free surface — a folded cloth under the cradle reduces ambient noise pickup noticeably.
  4. Wind the mainspring fully. A partially wound movement will show artificially low amplitude.
  5. Let the reading settle for 30–60 seconds before recording anything. The numbers fluctuate as the balance settles.
  6. Record the stabilised reading, then rotate to the next position.

The six standard positions are: dial up (DU), dial down (DD), crown up (CU), crown down (CD), crown left (CL), and crown right (CR). Measuring all six gives you a positional profile of the movement. Most collectors prioritise dial up and crown up because those reflect how the watch sits on a wrist during wear and in a watch box overnight. The mean of multiple runs across positions is the number worth trusting, not any single snapshot — multi-run averaging is standard practice precisely because a single run can be skewed by ambient vibration or a momentary power-reserve dip.

Temperature affects readings too. A cold movement straight from a display case will read differently from one at room temperature. Give the watch 15–20 minutes to acclimatise before testing.

Pro Tip: Wrap the timegrapher’s microphone cradle in a small piece of lint-free cloth. It dampens surface vibration without muffling the escapement tick, and the improvement in trace clarity is immediate.

Calibration of the device itself is straightforward but often skipped. Keep the microphone clean and free of dust, check that the lift-angle setting matches the calibre before every session, and store the machine away from strong magnetic fields. A timegrapher that has been sitting near a speaker or a magnetic clasp display can give subtly erratic readings until it is moved to a neutral environment.

Understanding rate, amplitude, beat error and lift angle

Rate (seconds per day)

Rate is the simplest number to read: positive means the watch is gaining, negative means it is losing. The COSC chronometer standard requires a rate within +6/−4 s/d across five positions and two temperatures. Most quality consumer movements are regulated to ±10–15 s/d from the factory, and a well-serviced movement of any tier should sit comfortably within ±15 s/d in the dial-up position.

Positional variance is where rate gets interesting. A movement that reads +2 s/d dial up but +35 s/d crown up has a poise or hairspring problem, not a regulation problem. Adjusting the regulator to split the difference would be the wrong fix.

Amplitude (degrees)

Amplitude is the single best indicator of movement health, and professional watchmakers treat a falling amplitude reading as the first warning sign of almost any mechanical failure. The balance wheel needs sufficient arc to function reliably; when amplitude drops, the escapement’s safety geometry starts to break down.

Healthy ranges by movement type:

  • Modern Swiss (e.g. ETA 2824, Sellita SW200): 270–310° dial up at full wind
  • Vintage movements (pre-1970s): 220–270° is often acceptable given age and oil condition
  • High-beat movements (36,000 vph): can run slightly lower, around 260–290°

Amplitude below 240° at full wind is a clear service indicator. The most common causes are dried lubricants creating friction, a weakened mainspring, or a worn jewel. Dried oil and friction are the most frequent culprits, and they show up in amplitude long before they cause the watch to stop entirely.

Beat error (milliseconds)

Beat error measures the symmetry of the tick and tock. A perfect beat error is 0.0 ms, meaning the escapement releases each tooth of the escape wheel at perfectly equal intervals. In practice, anything below 0.5 ms is excellent, 0.5–0.8 ms is acceptable for most movements, and above 1.0 ms the asymmetry starts to affect positional performance.

Beat error rarely causes a watch to stop, but a high value makes it harder to regulate accurately across positions. If you are buying a watch and the seller quotes a good rate but the beat error is 1.5 ms, the rate figure is less meaningful than it looks.

Lift angle and why it matters

Lift angle is an input, not a measurement, but getting it wrong produces amplitude readings that are meaningless. A wrong lift-angle setting can skew amplitude by 10–20%, which is enough to make a movement in need of service look healthy, or vice versa. Common values are approximately 50° for many ETA and Sellita calibres, 49° for some Miyota movements, and 53° for Seiko NH-series calibres.

Parameter Normal range Common causes of deviation Immediate action
Rate ±10 s/d (consumer); ±6/−4 s/d (COSC) Regulation, magnetism, positional poise Demagnetise, then regulate
Amplitude 270–310° (modern); 220–270° (vintage) Dried oil, weak mainspring, worn jewel Service if below 240° at full wind
Beat error 0.0–0.5 ms (excellent); up to 0.8 ms (acceptable) Beat-setting misalignment, hairspring Adjust beat setting; above 1.2 ms, send for service
Lift angle Calibre-specific input Wrong entry skews amplitude Verify against calibre spec before testing

Reading the trace: what the graph lines tell you

The numeric summary is only half the story. The acoustic trace — the paper strip or on-screen graph — encodes information that the averaged numbers smooth over. Experienced watchmakers look at the strip first, then use the three numbers to refine the diagnosis.

Timegrapher acoustic trace and controls close-up

A healthy trace shows two parallel, straight lines running at a consistent slope. The slope represents rate: a line angled upward to the right means the watch is gaining; flat is ideal; downward means losing. The gap between the two lines represents beat error. Tight, parallel lines with minimal scatter mean the movement is stable.

Pattern dictionary:

  • Split or widely spaced lines: beat error is high; the escapement is releasing unevenly
  • Wavy or sinusoidal lines: the rate is fluctuating, often pointing to hairspring fouling, a coil touching the regulator pins, or positional friction
  • Sudden jumps or scattered dots: gear-train noise, a loose part, or external vibration during the test
  • Extremely steep slope: the rate is wildly fast, which is the classic signature of magnetism; a magnetised hairspring clumps its coils together and shortens the effective length
  • Gradually widening line gap: beat error is drifting, sometimes caused by a loose cannon pinion or a hairspring that is not centred

A steep, erratic trace combined with a rate of +60 s/d or worse almost always means magnetism. Before sending the watch anywhere, pass it through a demagnetiser and retest. The trace will often normalise completely, and the rate will drop back into a sensible range within minutes. If it does not, the problem is mechanical, not magnetic.

Community-shared trace examples on forums like The Watch Forum are worth studying alongside technical guides because they show the messy real-world patterns that textbook diagrams rarely capture.

Real-world example readings

Case 1: High rate, good amplitude
Rate: +22 s/d dial up, amplitude 285°, beat error 0.3 ms. The movement is healthy — amplitude and beat error are both clean. The problem is simply regulation. A watchmaker can adjust the regulator lever to bring the rate within specification without any disassembly. This is the best-case scenario for a buyer: the watch works well and needs only a minor adjustment.

Real-world example readings — overview diagram

Case 2: Low amplitude across all positions
Rate: +5 s/d dial up, amplitude 225°, beat error 0.4 ms. The rate looks fine, but an amplitude of 225° at full wind is a service indicator regardless of the other numbers. Measured across all six positions, amplitude stays below 240° throughout. This movement needs a full service: cleaning, fresh lubricants, and an inspection of the mainspring. Amplitude decline across positions is one of the most reliable signals that lubrication has broken down.

Case 3: Good numbers, large positional variance
Rate: +4 s/d dial up, +38 s/d crown up, amplitude 290° in both positions, beat error 0.5 ms. The amplitude is healthy and the beat error is fine, but a 34 s/d swing between positions points to a poise issue or a hairspring that is not sitting flat. Demagnetising first is always worth trying, but if the positional variance persists after demagnetisation, the movement needs a watchmaker’s eye.

Before-and-after note: a watch showing +55 s/d and a steep, erratic trace was demagnetised using a standard bench demagnetiser. On retest five minutes later, the rate read +8 s/d and the trace lines were straight and parallel. No disassembly required.

Buyer checklist — what to ask when you see a timegrapher reading:

  • Was the movement fully wound before testing?
  • Which position was the reading taken in? (Dial up only is not enough.)
  • What lift angle was entered, and does it match the calibre?
  • Has the watch been demagnetised recently?
  • Are readings available across multiple positions, or just one?

Smartphone apps versus dedicated timegraphers

Smartphone apps that use the phone’s microphone — such as Watch Accuracy Meter — can give you a useful rate reading in a quiet room. They are genuinely handy for quick trend monitoring: testing the same watch weekly to see whether rate is drifting. What they cannot do reliably is measure amplitude. The phone’s microphone lacks the isolation and sensitivity of a bench machine’s contact microphone, and apps are best treated as trend monitors rather than instruments for final regulation.

Entry-level bench machines in the Weishi style cost roughly £80–£180 and are entirely adequate for a collector who wants reliable amplitude and rate readings. The jump to a professional Witschi-grade machine is justified when you are doing trade work, regulating high-value watches for sale, or need the detailed trace analysis that entry-level machines display less clearly.

When you need hardware rather than an app:

  • Regulating a movement to a specific rate target
  • Assessing amplitude to decide whether a service is due
  • Buying or selling a watch where accuracy claims need to be verified
  • Any trade or commercial context where the reading will be shared with a customer

What a timegrapher cannot tell you

A timegrapher is a diagnostic entry point, not a complete health check. It can identify timing errors and regulation problems, but it cannot detect mechanical wear in the gear train, internal case damage, or water-resistance failures. A movement can produce perfectly acceptable numbers on the bench and still have a worn pivot, a cracked jewel, or a case gasket that has hardened and will let water in.

Research into dynamic measurement confirms that static bench readings do not capture the full range of amplitude and rate variation a watch experiences during wear. Posture changes, wrist movement, and temperature fluctuations all affect performance in ways a bench test cannot replicate.

Clear service triggers — send the watch to a professional when:

  • Amplitude is below 240° dial up at full wind
  • Amplitude drops suddenly after the watch has been near electronics or a speaker (magnetism, but also worth a service check)
  • Beat error exceeds 1.2 ms and does not respond to beat-setting adjustment
  • Rate varies by more than 30 s/d between positions after demagnetisation
  • The trace is consistently erratic or scattered across multiple test runs
  • The watch has not been serviced in the past 5–7 years, regardless of current readings

Simple steps to try before sending it away:

  1. Demagnetise using a bench demagnetiser and retest.
  2. Wind fully and wait 60 seconds before recording.
  3. Test across all six positions and compare.
  4. Repeat the test the following day to check for consistency.

If the readings improve after demagnetisation and remain stable over several days, the watch may only need regulation. If they do not, professional watch repair is the right next step. Understanding why watches lose time can also help you frame the diagnosis before speaking to a technician.

Quick troubleshooting and regulation tips

Most problems a timegrapher reveals fall into one of three categories: magnetism, regulation, or a need for service. The order matters — always rule out magnetism first, because it mimics mechanical faults convincingly.

Do and don’t checklist:

  • Do demagnetise before drawing any other conclusion from a bad reading
  • Do wind fully before every test
  • Do measure all six positions and note the spread
  • Do record readings over several days to spot trends rather than relying on a single session
  • Don’t open the case or touch the regulator unless you are qualified to do so
  • Don’t adjust the lift-angle setting upward to make a low amplitude reading look better — this is a known seller tactic and produces a misleading result
  • Don’t assume a good dial-up reading means the watch performs well on the wrist; crown-up is the position that most closely reflects wrist wear overnight

Pro Tip: When setting lift angle for a calibre you have not tested before, cross-reference at least two sources — the manufacturer’s technical sheet and a calibre database. A 2° error in lift angle can shift the displayed amplitude by 10–15°, which is enough to misclassify a movement that genuinely needs service.

For regular servicing intervals and what to expect from a full overhaul, the trend data you collect over weeks of timegrapher testing is exactly what a technician needs to prioritise the work.

A watchmaker’s perspective: what professionals look for first

When a watch comes across the bench, amplitude is the first number I check — not rate. Rate tells you whether the watch is keeping time; amplitude tells you whether the movement has the energy to keep doing so reliably. A watch running at +20 s/d with 290° of amplitude is a regulation job. A watch running at +2 s/d with 215° amplitude is a service job, full stop, regardless of how tidy the rate looks.

The habit that separates a careful diagnosis from a guess is trend data. A single reading is a snapshot; three readings taken over a week, across multiple positions, is a picture. Amplitude that drops 15° between Monday and Friday without any change in use or storage is telling you something the numbers alone cannot: the movement is deteriorating, and the window for a straightforward service is closing.

Watchrepairstation’s trade partners benefit from a ‘No Fix, No Cost’ guarantee, which means a timegrapher reading that flags a potential issue never has to become a financial gamble for a shop. The reading is the starting point; the diagnostic check is where the real picture emerges. A timegrapher is an excellent tool. It is not a substitute for opening the movement.

Sources

Leave a Reply

Your email address will not be published. Required fields are marked *